Philips HeartStart FR3 Defibrillator with ECG
Manufacturer Product number: 861388
The HeartStart FR3 is Philips best professional-grade AED with advanced features for the professional responder. The FR3 reduces deployment time by eliminating steps and helps you start the right therapy on your patient faster.
Contact us on 01 5079900 for more information
What's Included?
- 10.8 volt 4.5 Ah Li-ion battery
- 2 pairs of multifunction adult/infant SMART III electrode pads
- Rescue kit
- 4-year battery
- User guide
- 5-year manufacturing warranty
Built to endure and designed for flexibility
The FR3 is built for harsh environments. It is tested to stringent military standards, meets IP55 rating for protection against dust and jetting water, and passes a 1,100 pound crush test. Its rechargeable battery option provides up to 100 shocks and 3 hours (with QCPR) of monitoring time. Plus, FR3 is a highly flexible platform so you can configure it for a wide range of current and evolving protocols.
Defibrillation
- Waveform: Truncated Exponential Biphasic.Waveform parameters adjusted as a function of patient impedance.
- Output Energy: Manual (selected): 1-10/15/20/30/50/70/100/120/150/170/200 Joules into a 50 Ohm load, AED Mode (single energy output): 150 Joules into a 50 ohm load. Joules/Ohm
- Charge Time: Less than 5 seconds to 200 Joules with a new/ fully charged lithium ion battery at 25º C
- Shock Delivery: Via multifunction defib electrode pads or paddles
- Shock-to-Shock Cycle Time: Typically less than 20 seconds seconds
- Minimum Patient Impedance Range: 15 Ohm (internal defibrillation); 25 Ohm (external defibrillation) Ohm
- Maximum Patient Impedance Range: 180 Ohm Ohm
- AED Mode: Shock advisory sensitivity and specificity meet AAMI DF-39 guidelines
Physical Dimensions
- Size with external paddles: 12.4" (W) x 7.7" (D) x 13.4" (H) (313 mm x 195 mm x 340 mm) "/mm
- Weight: 13.2 lbs. (6 kg): base unit with 1 battery/pads and pads cable. 13 lbs. (5.9 kg) with optional 75 mm strip chart printer. Paddle tray and external standard paddles add less than 2.5 lbs. (1.1 kg). Carrying case adds 4.1 lbs. (1.86 kg). lbs/kg
Physical dimensions Defibrillator model HeartStart MRx (M3536A)
- Size without external paddles: 12.4" (W) x 7.7" (D) x 11.7" (H) (313 mm x 195 mm x 295 mm) "/mm
CPR feedback and measurement:
- Compression Depth: Target: -1.50 to -2.00" (-38 to -51 mm) "/mm
- Compression Rate: Target: 90 to 120 cpm cpm
- Ventilation Volume: Graphic indicator: empty/one-third full/two-thirds full/full
- Ventilation Rate(a): Target for breaths delivered before 60 seconds since last compression: 6 to 16 vpm seconds/vpm
- Ventilation Rate(b): Target for breaths delivered beyond 60 seconds since last compression: 9 to 16 vpm seconds/vpm
SpO2 pulse oximetry
- Range: 0 to 100% %
- Resolution: 0,01%
- Alarm Range(a): Low Limit: 50 to 99% (Adult/Pediatric) %
- Alarm Range(b): High Limit: 51 to 100% (Adult/Pediatric) %
- Alarm Delay: 10 seconds
ECG and arrhythmia monitoring
- Input: Up to 4 ECG waves displayed and up to 3 ECG waves print simultaneously.
- Leads: Lead I, II, or III obtained through 3-lead ECG cable and separate monitoring electrodes. With 5-lead cable, obtain leads I/II/III/aVR/aVL/ aVF or V. Pads ECG obtained through 2 multifunction defibrillation electrode pads.
- Lead Fault: ‘Lead Off ’ message and dashed line displayed if an electrode or lead wire becomes disconnected.
- Pads Fault: Dashed line displayed if a pad becomes disconnected.
- Heart Rate Display: Digital readout on display 15 to 300 bpm with accuracy ±10% bpm/%
- Heart Rate/Arrhythmia Alarms: HR/Asystole/VFIB/VTACH/VTACH/extreme tachycardia/extreme bradycardia/PVC rate.
- ECG Size: 2.5/5/10/20/40 mm/mV autogain mm/mV
Noninvasive Blood Pressure
- Pressure Range(a): Systolic: 40 to 260 mmHg mmHg
- Pressure Range(b): Diastolic: 20 to 200 mmHg mmHg
- Initial Pressure: Adult: 160 mmHg and Pediatric: 120 mmHg mmHg
- Maximum Pressure: 280 mmHg mmHg
- Alarm Range(d): Systolic high limit: 30 - 270 (Adult) and 35 - 180 (Pediatric)
- Alarm Range(e): Systolic low limit: 30 - 265 (Adult) and 30 - 175 (Pediatric)
- Alarm Range(f):Diastolic high limit: 18 - 240 (Adult) and 18 - 150 (Pediatric)
- Alarm Range(g):Diastolic low limit: 10 - 240 (Adult) and 10 - 145 (Pediatric)
Physical
- Size: 2.7" high x 5.3" wide x 8.7" deep (6.9 cm x 13.5 cm x 22.1 cm)
- Weight:3 lbs 8 oz (1.6 kg) with FR3 standard battery installed
Environmental & physical requirements
- Solids/Water resistance: IP24
- Operating temperature: 0º - 45º C (32º - 113º F) ° C/° F
- Storage temperature: -20 - 70º C (-4º - 158º F) ° C/° F
- Operating humidity: 0% to 95% relative %
- Operating altitude:0 to 15000 ft (0 to 4500 m) ft/m
- Storage altitude: 0 to 15000 ft (0 to 4500 m) ft/m
- Mechanical shock: Bump: IEC 68-2-29, Freefall: IEC 68-2-32
- Operating vibration: MIL STD 810E 514.4 Category 6 Helicopter
- General storage vibration: UH60 Non-Operating: IEC 68-2-6 Swept Sine Vibration and IEC 68-2-64 Random Vibration
- Safety: Meets EN 60601-1, UL 2601-1/CSA C22.2 No. 601-1
Strip Chart Recorder
- Recorder(a): Standard: 50 mm (paper width) thermal array printer mm
- Recorder(b): Optional: 75 mm (paper width) thermal array printer mm
- Continuous ECG Strip: Prints primary ECG lead with event annotations and measurements in real-time or with 10-second delay
- Auto Printing: Recorder can be configured to print marked events/charge/ shock and alarms
- Reports: Event Summary, 12-Lead/Operational Check/ Configuration/Status Log and Device Information
- Paper Size: 1.97” (50 mm) W by 100 ft. (30 m) L and 2.95” (75 mm) W by 100 ft. (30 m) L "/ft/mm/m
Battery
- Type: 6.3 Ah, 14.8 V, rechargeable lithium ion Ah/V
- Dimensions: 6.5" (H) x 3.8" (W) x 1.6" (D) (165 mm x 95 mm x 42 mm) "/mm
- Weight: 1.6 lb. (0.73 kg) lb/kg
- Charge Time: Approximately 3 hours from fully depleted to 100%. 90 minutes from fully depleted to 80% hours/%
- Capacity(a): At least 5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring. With NBP every 15 minutes on one new fully charged battery.
- Capacity(b): At least 3.5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring. With NBP every 15 minutes and pacing at 180 ppm at 160 mA on one new fully charged battery. hours
Environmental
- Sealing: Meets IEC529 class IP55 with battery installed
- Temperature: Operating/standby: 32°–122°F (0°– 50°C)
- Altitude: 0 –15,000 feet (0 –4,572 meters)
Display
- Dimensions: 8.4" diagonal (128 mm x 171 mm) "/mm
- Type: TFT color LCD
- Resolution: 480 x 640 pixels (VGA) VGA
- Wave Viewing Time: 5 seconds (ECG) seconds
12-Lead ECG
- Input: 12-Lead cable: leads I/II/III/aVR/aVL/ aVF and V/C1-V/C6
- Display View: All 12-lead ECG waves display simultaneously
- Strip Recorder: All 12-leads print on the strip chart printer in 3x4 format
- Transmission: CompactFlash data card; Bluetooth® dial-up Internet connection, Bluetooth® FTP
End-tidal CO2
- Range: 0 to 99 mmHg mmHg
- Resolution: 1 mmHg (0.1 kPa) mmHg/kPa
- Sample Size: 50 ml per minute ml
- Alarm Range(h): Low Limit: 10 to 95 mmHg (Adult/Pediatric) mmHg
- Alarm Range(i): High Limit: 20 to 100 mmHg (Adult/Pediatric) mmHg
Data storage
- Internal: 12 hours of continuous ECG waveforms and events. Plus 50 12-lead ECG reports
- Data Card: 12 hours of continuous ECG waveforms and events. Plus 50 12-lead ECG reports on a CompactFlash memory card
ECG display
- Screen: LCD color display, 320 x 240 pixels. 2.8" x 2.1" (7.2 cm x 5.4 cm)
- Bandwidth: 1 Hz to 30 Hz (-3dB), nominal (non-diagnostic)
- Monitored Lead: Lead II using anterior-anterior adult pads placement
Environmental
- Shock/drop:Meets MIL-STD-810F 516.4, Procedure IV
- Patient Impedance Range: "Minimum: 15 ohm (internal defibrillation); 25 ohm (external defibrillation) Maximum: 180 ohm"
- Vibration: Meets MIL-STD-810F 514.5 C-17
- Abuse tolerance: After a ibe-meter drop to any edge, corner, or surface in standby mode
- AED Mode: Shock advisory sensitivity and specificity meet AAMI DF-39 guidelines